Home > Products > Distillation Columns & Scrubbing Towers Stainless Steel Distillation Columns & Scrubbing Towers | Custom Manufacturing Distillation Columns & Scrubbing Towers Distillation columns and scrubbing towers are core custom-engineered equipment in chemical separation and air pollution control. Distillation columns achieve multi-stage separation by exploiting differences in component volatility through counter-current gas-liquid contact, […]

Stainless Steel Distillation Columns & Scrubbing Towers | Custom Manufacturing

Distillation Columns & Scrubbing Towers

Distillation columns and scrubbing towers are core custom-engineered equipment in chemical separation and air pollution control. Distillation columns achieve multi-stage separation by exploiting differences in component volatility through counter-current gas-liquid contact, widely used in solvent recovery, fine chemical purification, and petrochemical refining. Scrubbing towers remove acid gases, particulate matter, and harmful components from industrial exhaust through liquid spraying or packed-bed absorption, meeting increasingly stringent emission standards.

As a professional stainless steel distillation column manufacturer and custom scrubbing tower supplier, Shandong Bojing Chemical Machinery has accumulated mature process expertise in the design and fabrication of both tower types. From media characterization, material selection, and internals design to welding fabrication and in-house pre-assembly, we apply rigorous process control throughout. For demanding conditions such as high throughput, severe corrosion, and fouling tendency, we ensure long-term stable operation through manufacturing process maturity.

Selection Parameters

ParameterTypical Range / Description
Equipment TypeTray distillation column, packed distillation column, spray scrubbing tower, packed scrubbing tower
Column DiameterDN300 – DN6000 (custom fabrication available)
Column HeightDesigned per theoretical stages and separation requirements, typically 6 – 40 m
Design PressureAtmospheric / slight positive / slight negative pressure, up to 2.5 MPa
Design Temperature-20°C – 350°C (depending on material and service)
Main Material304 / 304L / 316 / 316L / 2205 duplex / titanium / nickel-based alloy
Packing TypeRandom packing (Pall rings, cascade rings), structured packing (corrugated plate, wire mesh)
Tray TypeSieve, valve, bubble cap, jet tray
Spray Nozzle TypeSpiral, hollow cone, full cone, tangential
Mist EliminatorWire mesh, baffle plate, cyclone plate
Gas Handling Capacity1,000 – 300,000 m³/h (scrubbing tower)
Liquid-to-Gas RatioDesigned per absorption efficiency, typically 1 – 10 L/m³
Design StandardsGB/T 150, GB/T 151, HG/T 20584, NB/T 47003, etc.

Note: The above are typical parameter ranges. Specific selection requires custom design based on actual media, throughput, separation precision, and site conditions.

Why Choose Our Distillation Columns & Scrubbing Towers

  • Targeted weld HAZ inspection: From stainless steel selection to welding procedure qualification, heat input and post-weld heat treatment are controlled throughout, ensuring predictable service life under chloride-bearing conditions rather than sudden cracking after commissioning.
  • Material and design tailored to the medium: Selection and design are based on actual chloride concentration, temperature range, solids content, and crystallization tendency — not standard models that lead to selection deviation.
  • In-house pre-assembly and verification: Tower internals pre-installation, distributor levelness verification, nozzle atomization testing, and piping flush acceptance are completed before shipment, shortening on-site installation and accelerating production ramp-up.
  • Direct access to manufacturing engineers: From selection consulting to installation guidance and operational maintenance, engineers familiar with the fabrication process respond directly, helping customers avoid common engineering problems.

Common Engineering & Technical FAQs

This is typically chloride-induced stress corrosion cracking (Cl-SCC), with the root cause often traced to welding process control during fabrication. Experienced manufacturers intervene at the material selection stage: low-carbon or stabilized grades (such as 304L, 316L) are selected based on chloride concentration and temperature range in the medium, rather than relying on "stainless steel" as a blanket term. Heat input is strictly controlled during welding to avoid prolonged exposure in the 450–850°C sensitization range, and post-weld solution treatment or stabilization annealing is arranged per service requirements. Experienced fabrication teams also perform targeted inspection of weld heat-affected zones to ensure resistance to chloride attack after commissioning. The maturity of this entire process chain directly determines equipment service life under demanding conditions.

This is most likely fouling, plugging, and channeling in the packing layer, with the root cause often traced back to precision control during fabrication and assembly. If the levelness of packing support plates, installation elevation of liquid distributors, and uniformity of distribution holes exceed tolerances during fabrication, initial liquid distribution after commissioning will be uneven. Maldistribution gradually intensifies into "channeling," leaving large portions of packing surface unwetted. Experienced manufacturers incorporate distributor and support plate assembly precision into critical control points, completing pre-assembly and levelness verification in-house rather than relying on on-site adjustment. This experience in controlling distribution precision from the fabrication source is the dividing line between whether a tower achieves its design separation efficiency.

Scroll to Top

NEED HELP?

WELCOME TO CONTACT US

we are always ready to provide you with better quality and services. Welcome to contact us or visit our company and factory in the following ways

Contact Us